from the fixtures connected to each unit. Concrete Grease Interceptor Tanks Tanks are reinforced and constructed to ASTM Standards to include C-1613-06. Fill vault with clean water prior to beginning service. SIDE VIEW DETAIL INSTALLATION (1 of 2) page 3 of 5 WARNING! STEEL SEPARATORS, INTERCEPTORS,TRENCH DRAINS, & CATCH BASINS. Table I still applies. 612-GGI-2500 Grease Interceptor 2,500 Gal. Model #GB-250-FO 100 GPM Grease Interceptor For Indoor/Outdoor Use . Also consider that the NYC Department of Environmental Protection (DEP) performs routine inspections to ensure that grease interceptors receive proper maintenance and cleaning. 20GPM GREASE INTERCEPTOR 2"SPG. Using a pot scrubber with soap and room temperature water, remove excess waste from the lid and trap sides. Hydromechanical grease interceptors (HGI) (sometimes called grease traps) are installed indoors above or below the floor, or inground outside. The vent on the flow control is an air intake. grease interceptor, correctly designed to separate light densitysubstances from wastewater, will not by itself govern or regulate theflow of water through the interceptor at all times to sufficiently assurethe "flotation" separation of the substances which are to be interceptedat maximum efficiency. The retaining capacity is calculated separately for the fixtures in each table and the two values are then added. Grease interceptors, when combined with Best Management Practices (BMPs), will significantly reduce the amount of FOG entering the sewer system. Details and Specifications M.A.G. << /Predictor 1 Grease Interceptor - Direct-Bury, Typical Installation Drawing MGT-1. Please note, we update our standard details on a regular basis, so check back often to ensure you have the most recently published version. For this reason, they are also known as grease traps. The triple outlet feature allows for installation flexibility, including the ability to . While browsing our products, select Add to Quote Generator to quickly get an estimate for everything you need. ParkUSA, a Northwest Pipe Company, provides innovative water, wastewater, and stormwater equipment and technology for infrastructure and built environments. 48 State Delivery. ?eO[ao~~@77|*?-?}][}[WunWu_~ko-c9~|(Kze;M;Mw }_X7x~7-~-O=]X?ioUOWa_O7]/[=o7oYQ/8&{~o~~owW0"O~wyX~Gw};y]~Nnkw};!;o\|g:+/]w8e3'O=|x'sa,;'[o3[8z:PaB ysz}N7Z jK^fg)b+"eDDdc$D(86ME"E$X$:%%""hLn_U=g#/xK/Z#>AU,(>44M;t?3l/ww/e5~,b.dE18
{JEgwsQy'|8R>1Y
-D/tF=zC't@O/*M~]MS_RI~+P:TSFsZ>5Ti}f~})TJ"nV{{b'p|VA8q?p3U1mV^y]x!iIQ;VReUy+}M__k;#fD Adjustment should be checked after Interceptor is in operation. << /Length 103354 /Filter /FlateDecode /DecodeParms GREASE INTERCEPTOR SIZING PDI METHOD THREE COMPARTMENT SINK 1st - determine the cubic content of the fixture by multiplying length x width x depth. Hb```c``U1 2pt04 The GB-75 offers best-in-class certified grease capacity and 25% kitchen solids waste capacity. The tables can be viewed directly in the. rK|N^|a|C?W"^wjt> #JCzU{Wz8WR+8W}*Kiw9W2_KU2O,gW2Wge,9de}FFx/. In addition to NYC-specific requirements, grease interceptors are subject to national standards such as: The first step to specify grease interceptors is reviewing the kitchen layout and determining which equipment must be routed to grease traps. 75 GPM Hydromechanical Grease Interceptor. Sizing - PDI Method Using Sink Dimensions. Everything You Need to Know About Ghost Kitchens in 2022, Ghost Kitchens: An Emerging Trillion-Dollar Industry, 5 Reasons Why Steel Stairs are Great for Commercial Properties. %PDF-1.5
%
Grease rises to the top inside the interceptor and is trapped using a system of baffles. Draw-off valve available. Of course, there are also cases where the use of grease interceptors is obvious. The retention capacity of grease interceptors (in pounds) must be at least twice the numerical value of flowrate through the unit (in gallons per minute). Consult local codes for separate trapping requirements, cleanout locations and additional installation instructions. 56 0 obj
<>
endobj
73 0 obj
<>/Filter/FlateDecode/ID[<25FFE85CFD30298E93D6086510B62731><9C8D691145B44149AA34ADB177AFF0F4>]/Index[56 30]/Info 55 0 R/Length 96/Prev 669856/Root 57 0 R/Size 86/Type/XRef/W[1 3 1]>>stream
Solidified grease can cause stoppages downstream in piping systems and create costly and time-consuming problems at municipal wastewater treatment plants. Grease interceptors perform a fundamental role in. Specify M (Outlet opposite Inlet), L (Left Hand Outlet), or R (Right Hand Outlet) on your order. Grease Interceptor are manufactured with patented distributed flow pattern and corrosion resistant fiberglass material capturing FOG before it clogs pipes, enters the sewer waste system, or spoils a successful operation. Features. Grease interceptors are used in restaurants and other facilities. 4 0 obj
Installation must conform to local code. %PDF-1.6 Clean the trap sides, lids, and parts. Volume-Based Grease Interceptors. Installation Diagrams - Rockford Separators Protect waste lines against blocking and stoppages. It can be installed above grade (on the ground) or buried below grade (compatible with FCR2 risers to bring system to grade), as well as indoor or outdoor. >> According to the estimate, the average cost required to install a grease trap of 10 to 100 gallons is $250 to $1500. P: 972-842-8801, Kimberly JenkinsAtlanta, GAP: 706-506-2805, Impact of Flushable Wipes on Wastewater Treatment. Interceptors may be specified individually or for multiple fixtures at once, as allowed by the available space. Schier grease interceptors are not to be installed in any other manner except as shown. 7. MIFAB grease interceptors made from HDPE plastic making installation a breeze. Select a separator with a gallon-per-minute flow equal to the initial tank discharge capacity. Call 1-800-541-8004 for more information . CALL: Kim McDonald - ReWa / 864-419-7251 or Keith Moore - ReWa / 864-419-7051 Note: Not to scale 24-inch opening to accomodate a 24-inch secured manhole ring and cover 6x6x6 inch bafe wall tee must extend down within 18-20 inches from the bottom of the tank 6x6x6 inch inlet 90 tee shall extend . For example, scullery sinks and meat preparation sinks produce large amounts of grease, oils and solids. Any comment with external website links will not be published. The retained FOG should be regularly removed or pumped out of the interceptor. 454 0 obj
<>stream
The interceptor must be cleaned whenever 25 percent of any chamber becomes filled with FOG or solids. %PDF-1.3
%
Grease interceptors are used in plumbing systems to trap greases, oils and solid particles before they can reach the public sewage. Sale ends in: 6d 1h. hbbd```b``f+A$S9d@$&T.@$WX X: "^ IA v8l>#E
3
Do not install interceptor backward. For this reason, they are also known as grease traps. A recommendation not only for grease interceptors but for equipment in general is adhering to manufacturer instructions. The triple outlet feature allows for installation flexibility, including the ability to connect an unused outlet for remote pumpout (PP1 . General Guidelines for Grease Interceptor Installation. Their capacity is measured by the volume of water that flows through the fixture, which ranges from 20-50 gallons per minute. We manufacture and stock separators to meet these requirements. Grease interceptors are used in establishments to remove excessive amounts of grease that may interfere with the proper drainage and treatment of wastewater. Source: www.drain-tech.com Check Details. Core drill all penetrations in vault. A routine cleaning schedule will ensure maximum performance of each interceptor., Uniform Plumbing Code DFU Method - Gravity Grease Interceptor Sizing Tool, Meal Factor - Gravity Grease Interceptor Sizing Tools, Grease Interceptor - Concrete, Two Compartment, Direct-Bury, Grease Interceptor - Concrete, Three Compartment, Direct-Bury, Grease Interceptor - Stainless Steel, Two Compartment, Free-Standing, Grease Interceptor - Stainless Steel, Two Compartment, Direct Bury, GT - Fiberglass - Above Ground 500 - 5000 gal, GT - Fiberglass - Below Ground 500 - 5000 gal, GT - 3 Comp. Created By Granicus - Connecting People and Government. Next, use water to flush the parts and screens in order to get rid of debris and soap. Grease interceptors are available in recessed, semi-recessed and on-floor versions. of Environmental Protection places stringent requirements regarding their use, while carrying out routine inspection for units in operation. Grease interceptors are used in plumbing systems to trap greases, oils and solid particles before they can reach the public sewage. Click to change Location. Precast concrete interceptors shall conform to the . All sizes available for your grease trap needs. With an internal flow control, an external flow control is not necessary. HWr6&. Some dishwashers have lower waste openings than illustrated on the separators. Side connections are prohibited for inlet or outlet. An example is the Blakeslee dishwasher with a 3 center line waste outlet and with the new dry recirculating pump which requires that the static water level in the separator be lower than 9. Subscribe to the NY Engineers Blog below. ReWa Grease Interceptor Detail QUESTIONS? )GRGN
Sizing - PDI Method Using Sink Volumes. ?"_cyQjpXzH=/xZCCCP+y'SWzHyM2?zHmXy'zHmXzH=QqW~Ia}ox3whjXiwbNk'0Rccww^T\NkN=QAQS$d>o;|oa}I*v;sNTa}m hbspt.cta._relativeUrls=true;hbspt.cta.load(2004318, '42988b7d-d06c-4059-82e4-709ad6f267fd', {"useNewLoader":"true","region":"na1"}); For projects in New York City, only a Registered Design Professional (RDP) can submit commercial kitchen plumbing designs for approval by the NYC Department of Buildings, and only a Licensed Master Plumber (LMP) can carry out the actual installation. Install outlet tee with 6" diameter vertical riser. EXAMPLE: 1- three compartment sink EXAMPLE: Grease interceptors should be installed for any commercial kitchen equipment where grease may be released into drain pipes. Where to buy. a#7\*S$S`Rn3aH#{`hf08ClpM9 by\J#'Tm5v"s'. ^\kmtv\(iz~Rd;1pK]>KG@XXCno r!VtaM'N]eM#aM" wDn6"DY
O;(hH|1 15EL:Snf&0iSJ4hll[q.FXn?a20I' VX
J MvX=GmM
dhJ]9G"r>q,O&t5(4hl-EU6F>
yhhTfc4(p
sR-|I x*sL!,@G =6 QpH GH'@E9FUH! 3. endobj
INSTALLATION - GREASE INTERCEPTORS MULTIPLE FIXTURE INSTALLATIONS It is sometimes practical to discharge the waste from two or more sinks into a . If these values are exceeded, the grease interceptor capacity must be calculated by an NYC Registered Design Professional, based on data extrapolation. If you continue to use this site, you consent to the use of cookies. of Environmental Protection places stringent requirements regarding their use, while carrying out routine inspection for units in operation. The GB-250 offers best-in-class certified grease capacity and 25% kitchen solids waste capacity. Grease interceptors are used in establishments to remove excessive amounts of grease that may interfere with the proper drainage and treatment of wastewater. 0
PDI G101 mandates the installation of an vented external flow control. Also consider that the NYC Department of Environmental Protection (DEP) performs routine inspections to ensure that grease interceptors receive proper maintenance and cleaning. CALL TOLL FREE: 800-465-2736; . Z1174 Installation Instructions. Web grease interceptor sizing and installation guidelines. Grease Interceptor - Hydromechanical, 4 Thru 100 GPM . After a grease interceptor layout has been proposed, the next step is calculating the aggregate volume from the fixtures connected to each unit. Table I reaches up to 123,000 cubic inches, while Table II reaches up to 61,600 cubic inches. Interceptors prevent greasy substances from entering plumbing systems, septic fields, and waste water treat-ment facilities, where they are difficult to process, and can create environmental problems. You also need a grease recovery device that costs $3500 to $6000 estimated. 3 0 obj
Looking for a quote for your project? 5. Tab will move on to the next part of the site rather than go through menu items. Lard and other high-viscosity fats can also solidify as they cool down, trapping other solids and blocking sewage pipes. Romtec, Inc. Model 3012: Dimensional Lumber Pavilion Download DWG. Armatherm Thermal Bridging Solutions . Ferris, TX 75125
It can be installed above grade (on the ground) or buried below grade (compatible with FCR2 riser to bring system to grade), as well as indoor or outdoor. We also offer tanks for Industrial Waste, PH Adjustment and oil & water separation. Passive grease interceptors help food service establishments and food processing industries comply with EPA Sewer Pretreatment Regulations. Flow ANCHOR KIT INSTALLATION DETAIL 2-1/2" Minimum Insertion Depth 4" Maximum Insertion Depth (into GB unit only) FIELD CUT RISER (24 SERIES) INSTALLATION GUIDELINES Tools needed: 7/16" Nut driver tool/bit (included), marker (included), tape They are used to train mechanics, hotels, supermarkets and other Toilet Installation January 19, 2018 Canyon Lake, Hemet, Menifee, Moreno Valley, Perris, Southern California, Eastern Municipal Water District, CA -, August, Greater August Utility District, ME - Grease Interceptor, Timpanogos Special Utility District, Lehi City, UT - Grease Interceptor. Highstrength precast concrete, steel, or fiberglass, Precast concrete, fiberglass, or stainless steel construction, Interior liners include epoxy, high density polyethylene, and stainless steel, Free-standing and direct-bury configurations, Los Angeles, Long Beach, Anaheim, CA - Grease Interceptor GT-500, Austin, Round Rock, Georgetown, Pflugerville, TX - Grease, Wichita Falls, Iowa Park, Burkburnett, TX - Grease Interceptor GT-, San Diego, San Bernadino, Highland, FEWD Program, Carlsbad, CA -, Oceanside, Vista, San Marcos, CA - Grease Interceptor. Phone: 419-836-2300. x=r6?Q' SYUYeU{j}P,YF4oo{7.$s@9I
uLF6?W9|vyRyi:iNW*l?3xf?xjyQ G]
MFB9G]sV Schier considers both flow rate and grease production to determine the capacity of the interceptor and its recommended pumpout frequency. older versions (Use only for reference for previously approved projects) Mesa Engineering and Design Standards 2022 Engineering and Design Standards Manual [PDF] - Effective June 27, 2022 2022 Updates to the Engineering Design Standards [PDF] 43 CAD Drawings for Category: 46 25 23 - Grease Traps. >> For calculation of grease interceptor retaining capacity, the NYC Department of Environmental Protection provides two tables, each with interceptor capacity values (in pounds) corresponding to aggregate volume from kitchen fixtures (in cubic inches). endstream
endobj
426 0 obj
<. Reinstall the grease trap. Using manual valves to reduce flow to a grease interceptor is not allowed. Equivalency must be demonstrated with detailed documentation and calculations. of free standing in an above grade installation, as applicable. Please avoid adding links in comments. <>/ExtGState<>/XObject<>/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/MediaBox[ 0 0 612 792] /Contents 4 0 R/Group<>/Tabs/S/StructParents 0>>
<>
P: 713-937-7602Toll Free: 888-611-7275, 8491 Hwy 87 EastSan Antonio, TX 78263P: 210-227-7275, 1200 N Fwy Service Rd
Interceptor shall be installed and connected so that it is accessible at all times for inspection, cleaning, and removal of intercepted grease. cHl a4 3030`\ (|0bE^lRL)/8 U? Mesaaz.gov is undergoing a redesign! In the last 20 years we have grown from a small regional company to the most widely specified brand of grease interceptors in the U.S. Grease Trap Pit is a precipitation system designed to trap grease and suspended sediment in industrial wastewater. of Environmental Protection website. They are very important for public hygiene, and the NYC Dept. It can be installed above grade (on the ground) or buried below grade (compatible with FCR2 riser to bring system to grade), as well as indoor or outdoor. %PDF-1.5
%
Access Access requirements shall follow WSSC Code 302.10.1/1003.6.2.6 & 1003.6.2.7 and WSSC Standard Details. stream
29 0 obj
<<
/Linearized 1
/O 31
/H [ 1314 270 ]
/L 478682
/E 423469
/N 3
/T 477984
>>
endobj
xref
29 44
0000000016 00000 n
0000001227 00000 n
0000001584 00000 n
0000001791 00000 n
0000002056 00000 n
0000002917 00000 n
0000003213 00000 n
0000003727 00000 n
0000004530 00000 n
0000004991 00000 n
0000005385 00000 n
0000005674 00000 n
0000006532 00000 n
0000006571 00000 n
0000007375 00000 n
0000008179 00000 n
0000008202 00000 n
0000027838 00000 n
0000027861 00000 n
0000046369 00000 n
0000046392 00000 n
0000058652 00000 n
0000058675 00000 n
0000070930 00000 n
0000070953 00000 n
0000083362 00000 n
0000083385 00000 n
0000095676 00000 n
0000095699 00000 n
0000108048 00000 n
0000108071 00000 n
0000121155 00000 n
0000124972 00000 n
0000126110 00000 n
0000130219 00000 n
0000130358 00000 n
0000130496 00000 n
0000418973 00000 n
0000420291 00000 n
0000422991 00000 n
0000423108 00000 n
0000423213 00000 n
0000001314 00000 n
0000001563 00000 n
trailer
<<
/Size 73
/Info 28 0 R
/Root 30 0 R
/Prev 477974
/ID[]
>>
startxref
0
%%EOF
30 0 obj
<<
/Type /Catalog
/Pages 17 0 R
/JT 27 0 R
/PageLabels 16 0 R
>>
endobj
71 0 obj
<< /S 55 /L 179 /Filter /FlateDecode /Length 72 0 R >>
stream
,Ma0kiE"[*cb\ivF}ntC~\>a{.6y - FRP - Below Ground 500 - 5000 gal, Grease Interceptor - Direct-Bury, Typical Installation Drawing, Grease Interceptor - Hydromechanical, 4 Thru 100 GPM, Grease Interceptor - Hydromechanical, 150 Thru 500 GPM, Sample Well, Concrete, Direct -Bury, with Equal Inverts, Sample Well, Concrete, Direct -Bury, with Unequal Inverts, Sample Well, Stainless Steel, Above-Ground, Albuquerque, NM - Grease Interceptor GT-500 Thru GT-1000, Denver, CO - Grease Interceptor GT-500 Thru GT-4000, Los Angeles, Long Beach, Anaheim, CA - Grease Interceptor GT-500 Thru GT-4000, Corpus Christi, TX - Grease Interceptor GT-500 Thru GT-2000, Corpus Christi, TX - Grease Interceptor GT-2500 Thru GT-10000, Austin, Round Rock, Georgetown, Pflugerville, TX - Grease Interceptor GT-500 Thru GT-4000, Austin, Round Rock, Georgetown, Pflugerville, TX - Grease Interceptor GT-5000 Thru GT-15000, Wichita Falls, Iowa Park, Burkburnett, TX - Grease Interceptor GT-500 Thru GT-4000, Wichita Falls, Iowa Park, Burkburnett, TX - Grease Interceptor GT-5000 Thru GT-15000, Lubbock, TX - Grease Interceptor GT-500 Thru GT-4000, Lubbock, TX - Grease Interceptor GT-5000 Thru GT-15000, City of Little Rock, AR - Grease Interceptor GT-500 Thru GT-4000, Murray City, UT - Grease Interceptor GT-1000 Thru GT-4000, Orem, UT - Grease Interceptor GT-1000 Thru GT-4000, St. George, UT - Grease Interceptor GT-500 Thru GT-4000, Tacoma, WA - Grease Interceptor GT-1000 Thru GT-4000, Tacoma, WA - Grease Interceptor GT-5000 Thru GT-15000, San Diego, San Bernadino, Highland, FEWD Program, Carlsbad, CA - Grease Interceptor GT-1000 Thru GT-4000, Oxnard, CA - Grease Interceptor GT-1000 Thru GT-4000, Oceanside, Vista, San Marcos, CA - Grease Interceptor GT-1000 Thru GT-4000, Canyon Lake, Hemet, Menifee, Moreno Valley, Perris, Temecula, CA - Grease Interceptor GT-1000 Thru GT-4000, Southern California, Eastern Municipal Water District, CA - Grease Interceptor GT-1000 Thru GT-4000, Murfreesboro, Nashville, TN - Grease Interceptor GT-1000 Thru GT-4000, August, Greater August Utility District, ME - Grease Interceptor GT-1000 Thru GT-4000, Leesburg, FL - Grease Interceptor GT-1000 Thru GT-4000, Timpanogos Special Utility District, Lehi City, UT - Grease Interceptor GT-1000 Thru GT-4000, Provo, UT - Grease Interceptor GT-1000 Thru GT-4000, 201 NE Park Plaza DriveSuite 100, Vancouver, WA 98684P: 360-397-6250, 7015 Fairbanks N Houston